IMMUNITY (EMC/RFI) TESTING SERVICES
|
|
|
|
EN 61000-4-2 Electro-Static Discharge (ESD) Immunity
|
|
|
Our Electro-static Discharge Immunity test
setup can provide up to 8 kV of contact
discharge and 15 kV of Air discharge covering
a wide variety of family product requirements.
|
|
|
|
|
EN 61000-4-3 Radiated Radio-Frequency (RF) Immunity
|
Pictured to the left is our BiconiLog
antenna used for Radiated RF Immunity
testing to EN 61000-4-3 and for
prescanning of products to Radiated
Emissions standards such as FCC Part 15,
IC ES 003 and EN 55022:1994. The chamber
can generate fields up to 10 volts per
meter and has been calibrated per the
uniform field requirements of EN
61000-4-3 at 3 and 10 volts per meter.
|
|
|
|
|
EN 61000-4-4 Electrical Fast Transient (EFT) Immunity
|
|
|
The Electrical Fast Transient test system
can provide up 4 kV on single phase 230
Volt 16 Amp mains power and up to 2 kV
via a coupling clamp onto I/O cables.
|
|
|
|
|
|
|
EN 61000-4-5 Surge Immunity
|
|
|
Surge Immunity onto Mains powered single
phase 230 VAC, 16 Amp devices can be
applied up to 4 kV and I/O cables can be
surged up to 2 kV via a coupling network.
|
|
|
|
EN 61000-4-11 Voltage Dips, Interrupts and Short Variations Immunity
|
|
|
|
Voltage Dips and Short Interruptions 0 to
100 % onto Mains powered single phase 230
VAC, 16 Amp devices.
|
|
|
|
|
EN 55020 TEM Cell Immunity
|
|
|
A Transverse Electro-Magnetic (TEM) Cell is an open stripline that
maintains its characteristic impedance throughout its volume.
Electrical and magnetic fields from 150 kHz to 150 MHz.
|
|
|